; Run the 7970B/E nine-track magnetic tape diagnostic (D433A). ; ; Test with one 7970B, automatic test 3. ; Set up the log(s). set -n console log=zmtb3.log set -n console debug=debug.log ; Configuration locations: ; ; Location Default Value Contents ; ------------- ------------- --------------------------------------------------- ; DB+0 047574 000000 Switch Register setting ; DB+1 047575 077414 Section Select Register setting ; DB+2 047576 000014 Version and update level ; DB+3 047577 000000 0 Magnetic tape DRT number ; DB+4 047600 000143 99 Maximum error print count ; DB+5 047601 000000 Section number ; DB+6 047602 000000 Step number ; DB+7 047603 000000 Device status ; Boot the I/O diagnostics tape. attach -r ms0 30000-11017_Rev-2640_IO.tape boot ms0 ; Load the tape file containing the diagnostic. ; ; The I/O tape contains these files: ; ; DIAGNOSTIC FILE REV %FILE ; ------------------- ------ ----- ---- ; SLEUTH PD411A 01.05 (01) ; CART DISC-7905A PD419A 01.04 (02) ; MEMORY PATTERN PD421A 01.00 (03) ; MULTIPLEXOR CHAN PD422A 01.02 (04) ; DISC FILE-2888A PD423A 01.00 (05) ; CART DISC-7900A PD424A 01.00 (06) ; SYSTEM CLOCK II/III PD425A 01.00 (07) ; SYS CLK/FLI III-LC PD426A 00.00 (10) ; TERMINAL DATA PD427A 01.01 (11) ; FIXED HEAD DISC PD428A 01.00 (12) ; SELECTOR CHAN PD429A 01.01 (13) ; FLT.CORR.MEM SER-II PD430A 01.01 (14) ; FLT.CORR.MEM SER-III PD430B 00.00 (15) ; EXTEND INSTRUC SET PD431A 01.00 (16) ; HSI DIAG. PD432A 01.00 (17) ; MAGNETIC TAPE PD433A 01.04 (20) ; SSLC INTERFACE PD434A 01.03 (21) ; ASLC INTERFACE PD434B 01.04 (22) ; UI DIAG PD435A 01.01 (23) ; TERMINAL CONTROL PD438A 01.00 (24) ; CALCOMP PLOTTER PD439A 01.01 (25) ; COBOLII A F/W DIAG PD441A 00.00 (26) ; COBOLII B F/W DIAG PD442A 00.00 (27) ; STAND ALONE DISC SADUTIL 01.00 (30) deposit SWCH 20 ; Set the tape unit modes. set ms0 7970B,reel=600 ; Set the CLK into diagnostic mode. set clk realtime ; Run the diagnostic. set console delay=10000 set -a -i console halt=Q010 TAPE DEVICE NUMBER? echo echo Press to start the diagnostic. go ; Respond to "Q010 TAPE DEVICE NUMBER?" set console response=6~m set -a -i console halt=Q011 TIMER DEVICE NUMBER? go ; Respond to "Q011 TIMER DEVICE NUMBER?" set console response=3~m set -a -i console halt=Q012 MAXIMUM ERROR PRINT COUNT? go ; Respond to "Q012 MAXIMUM ERROR PRINT COUNT?" set console response=100~m set -i console halt=YOUR CODE? go ; Respond to "P005 TYPE FOLLOWING CONTROL ; A'CR'-AUTO, R'CR'-RESTART, ; M'CR'-MANU, 'CR'-RESUME, YOUR CODE?" set console response=A~m set -i console halt=CHANGE?(YES/NO) go ; Respond to "D015 PRESENT SECTION REGISTER:%077414 DO YOU WISH TO CHANGE?(YES/NO)" set console response=YES~m set -a -i console halt=D015 UPDATE SECTION REGISTER:% go ; Respond to "D015 UPDATE SECTION REGISTER:%" ; ; Section Select options: ; ; bit 0 = not used ; bit 1 = execute section 1 (auto - basic control) ; bit 2 = execute section 2 (auto - control, dev, status, space) ; + bit 3 = execute section 3 (auto - file mark, 800 cpi only) ; bit 4 = execute section 4 (auto - CRCC, dropout) ; bit 5 = execute section 5 (auto - timing) ; bit 6 = execute section 6 (auto - BOT, EOT, creeping) ; bit 7 = execute section 7 (auto - read/write) ; bit 8 = not used ; bit 9 = not used ; bit 10 = not used ; bit 11 = execute section 11 (manual - head test) ; bit 12 = execute section 12 (manual - start/stop) ; bit 13 = execute section 13 (manual - reel protection) ; bit 14 = execute section 14 (manual - tape test) ; bit 15 = execute section 15 (manual - write/read) ; ; The default section select setting is 077414. set console response=010000~m set -i console halt=CHANGE?(YES/NO) go ; Respond to "D015 PRESENT SECTION REGISTER:%000010 DO YOU WISH TO CHANGE?(YES/NO)" set console response=NO~m set -a -i console halt=Q020 DRIVE 0? go ; Respond to "Q019 AUTO-PROCESS: ENTER TAPE UNIT(B,E,NO) AT ; Q020 DRIVE 0?" set console response=B~m set -a -i console halt=Q020 DRIVE 1? go ; Respond to "Q020 DRIVE 1?" set console response=NO~m set -a -i console halt=Q020 DRIVE 2? go ; Respond to "Q020 DRIVE 2?" set console response=NO~m set -a -i console halt=Q020 DRIVE 3? go ; Respond to "Q020 DRIVE 3?" set console response=NO~m set -a -i console halt=Q030 ALL DEFINITIONS CORRECT(YES/NO)? go ; Respond to "P003 UNLOAD PROGRAM TAPE - LOAD TEST TAPE(S) ; Q030 ALL DEFINITIONS CORRECT(YES/NO)?" attach -n ms0 scratch.tape set console response=YES~m set -a -i console halt=P011 UPDATE SWITCH REGISTER (CR) go ; Respond to "P011 UPDATE SWITCH REGISTER (CR)" ; Set the Switch Register options: ; ; + bit 0 = select the external switch register ; bit 1 = modify the Section Select Register ; bit 2 = not used ; bit 3 = not used ; bit 4 = not used ; bit 5 = not used ; bit 6 = not used ; bit 7 = output D,E-class messages to the line printer (if configured) ; bit 8 = not used ; bit 9 = suppress E-class messages ; bit 10 = suppress D-class messages ; bit 11 = loop on the current step ; + bit 12 = halt on error ; bit 13 = halt at the end of each step ; bit 14 = halt at the end of each section ; + bit 15 = halt at the end of each diagnostic pass deposit SWCH 100011 ; Set the debugging options. ; set cpu debug set iop debug=irq;dio,filter=3;7 set mpx debug ; set clk debug set ms debug ; =============== ; Test section 5. ; =============== set ms realtime set console response=~m set -a console halt=P010 PAUSE AT PASS 01 go ; End the of diagnostic. set console nohalt