; Run the 7905 disc diagnostic (D419A). ; ; Test with two 7905 drives, automatic test sections 0 and 2-6, long pass. ; Set up the log(s). set -n console log=zdsml.log ; Configuration locations: ; ; Location Default Value Contents ; ------------- ------------- --------------------------------------------------- ; DB+0 041300 100000 Switch Register setting ; DB+1 041301 177000 Section Select Register setting ; DB+2 041302 000014 Version and update level ; DB+3 041303 000000 Disc controller DRT number ; DB+4 041304 000143 99 Maximum error print count ; DB+5 041305 000000 Section number ; DB+6 041306 000000 Step number ; DB+7 041307 000000 Device status ; Boot the I/O diagnostics tape. attach -r MS0 30000-11017_Rev-2640_IO.tape boot MS0 ; Load the tape file containing the diagnostic. ; ; The I/O tape contains these files: ; ; DIAGNOSTIC FILE REV %FILE ; ------------------- ------ ----- ---- ; SLEUTH PD411A 01.05 (01) ; CART DISC-7905A PD419A 01.04 (02) ; MEMORY PATTERN PD421A 01.00 (03) ; MULTIPLEXOR CHAN PD422A 01.02 (04) ; DISC FILE-2888A PD423A 01.00 (05) ; CART DISC-7900A PD424A 01.00 (06) ; SYSTEM CLOCK II/III PD425A 01.00 (07) ; SYS CLK/FLI III-LC PD426A 00.00 (10) ; TERMINAL DATA PD427A 01.01 (11) ; FIXED HEAD DISC PD428A 01.00 (12) ; SELECTOR CHAN PD429A 01.01 (13) ; FLT.CORR.MEM SER-II PD430A 01.01 (14) ; FLT.CORR.MEM SER-III PD430B 00.00 (15) ; EXTEND INSTRUC SET PD431A 01.00 (16) ; HSI DIAG. PD432A 01.00 (17) ; MAGNETIC TAPE PD433A 01.04 (20) ; SSLC INTERFACE PD434A 01.03 (21) ; ASLC INTERFACE PD434B 01.04 (22) ; UI DIAG PD435A 01.01 (23) ; TERMINAL CONTROL PD438A 01.00 (24) ; CALCOMP PLOTTER PD439A 01.01 (25) ; COBOLII A F/W DIAG PD441A 00.00 (26) ; COBOLII B F/W DIAG PD442A 00.00 (27) ; STAND ALONE DISC SADUTIL 01.00 (30) deposit SWCH 2 ; Set the CLK into diagnostic mode. set CLK realtime ; Configure the disc drives. set DS0 7905,format attach -n DS0 scratch.0.disc set DS1 7905,format attach -n DS1 scratch.1.disc ; Run the diagnostic. set console delay=10000 set -a console halt=Q99 02 echo echo Press to start the diagnostic. go ; Respond to "Q99 02 DECIMAL DEVICE NUMBER?" set console response=4~m set -a console halt=Q99 03 go ; Respond to "Q99 03 MAXIMUM ERROR PRINT COUNT?" set console response=999~m set -a console halt=P99 55 go ; Respond to "P99 55 UPDATE SWITCH REGISTER" ; ; Set the Switch Register options: ; ; + bit 0 = select the external switch register ; + bit 1 = modify the Section Select Register ; bit 2 = skip CLEAR in ENDSTEP when disc drive error (STATUS2) appears ; bit 3 = not used ; bit 4 = not used ; bit 5 = not used ; bit 6 = not used ; bit 7 = output D,E-class messages to the line printer (if configured) ; bit 8 = not used ; bit 9 = suppress E-class messages ; bit 10 = suppress D-class messages ; bit 11 = loop on the current step ; bit 12 = pause on error ; bit 13 = pause at the end of each step ; bit 14 = pause at the end of each section ; bit 15 = pause at the end of each diagnostic pass echo echo sim> deposit SWCH 140000 echo sim> go deposit SWCH 140000 set console response=~m set -a console halt=Q99 61 go ; Respond to "Q99 61 RESTART?(YES/NO)" set console response=NO~m set -a console halt=Q99 06 go ; Respond to "Q99 06 PRESENT SECTION REGISTER: %177000 DO YOU WISH TO CHANGE?(YES/NO)" set console response=YES~m go ; Respond to "Q99 06 UPDATE SECTION REGISTER: %" ; ; Section Select options: ; ; + bit 0 = execute section 0 (verifying of basic functions) ; bit 1 = execute section 1 (verifying all functions) ; + bit 2 = execute section 2 (write/read to all or limited addresses) ; + bit 3 = execute section 3 (random write/read with random block size) ; + bit 4 = execute section 4 (random one block read unique data) ; + bit 5 = execute section 5 (multi-unit tets same as section 4) ; + bit 6 = execute section 6 (interface test in test mode) ; + bit 7 = change unit table ; bit 8 = change cylinder table ; bit 9 = change head table ; bit 10 = change pattern data table ; bit 11 = loop on current section ; bit 12 = not used ; bit 13 = shorten test somewhat ; bit 14 = shorten test severely ; bit 15 = restrict cylinders are not used ; ; The default section select setting is 177000. set console response=137400~m go ; Respond to "Q99 06 PRESENT SECTION REGISTER: %137400 DO YOU WISH TO CHANGE?(YES/NO)" set console response=NO~m set -a console halt=Q99 09 go ; Respond to "Q99 09 WISH TO ALTER TABLE?" set console response=YES~m set -a console halt=Q99 10 go ; Respond to "Q99 10 ENTER UNIT NUMBERS SEPARATED BY COMMAS" set console response=0,1~m set -a console halt=Q99 09 go ; Respond to "Q99 09 WISH TO ALTER TABLE?" set console response=NO~m set -a console halt=P99 51 go ; Respond to "P99 51 RESET SWITCH 1 (CHANGE)" ; ; Set the Switch Register options: ; ; + bit 0 = select the external switch register ; bit 1 = modify the Section Select Register ; bit 2 = skip CLEAR in ENDSTEP when disc drive error (STATUS2) appears ; bit 3 = not used ; bit 4 = not used ; bit 5 = not used ; bit 6 = not used ; bit 7 = output D,E-class messages to the line printer (if configured) ; bit 8 = not used ; bit 9 = suppress E-class messages ; bit 10 = suppress D-class messages ; bit 11 = loop on the current step ; bit 12 = pause on error ; bit 13 = pause at the end of each step ; bit 14 = pause at the end of each section ; + bit 15 = pause at the end of each diagnostic pass echo echo sim> deposit SWCH 100001 echo sim> go deposit SWCH 100001 set console response=~m set -a console halt=P99 05 go ; Respond to "P99 05 RESET BOTH PROT.DATA SWITCHES,SET SWITCH FORMAT AND SET UNIT TO 0" set console response=~m set -a console halt=Q99 42 go ; Respond to "Q99 42 WISH TO EXECUTE INTERACTIVE PORTION IN SECTION 1 (YES/NO)" set console response=NO~m set -a console halt=P92 47 go ; End the of diagnostic. Restore the hardware configuration. detach DS0 detach DS1 ! del scratch.0.disc scratch.1.disc