; Memory Pattern Test diagnostic (D421A). ; Parameter 1 = path to diagnostic tape. ; ; (no documentation, so I've guessed below) ; ; Configuration locations: ; ; Location Default Value Contents ; ------------- ------------- --------------------------------------------------- ; DB+0 016114 100010 Switch Register setting ; DB+1 016115 000000 Section Select Register setting ; DB+2 016116 000000 Version and update level ; DB+3 016117 000000 ? ; DB+4 016120 000144 100 ? Maximum error print count ; DB+5 016121 000003 3 ? System clock DRT number ; DB+6 016122 000001 ? ; DB+7 016123 000001 ? echo echo echo -------------------------- echo D421 - Memory Pattern Test echo -------------------------- echo echo Loading the stand-alone loader. ; Cold load the I/O diagnostics tape. attach -r MS0 %130000-11017_Rev-2640_IO.tape boot MS0 ; Load the tape file containing the diagnostic. ; ; The I/O tape contains these files: ; ; DIAGNOSTIC FILE REV %FILE ; ------------------- ------ ----- ---- ; SLEUTH PD411A 01.05 (01) ; CART DISC-7905A PD419A 01.04 (02) ; MEMORY PATTERN PD421A 01.00 (03) ; MULTIPLEXOR CHAN PD422A 01.02 (04) ; DISC FILE-2888A PD423A 01.00 (05) ; CART DISC-7900A PD424A 01.00 (06) ; SYSTEM CLOCK II/III PD425A 01.00 (07) ; SYS CLK/FLI III-LC PD426A 00.00 (10) ; TERMINAL DATA PD427A 01.01 (11) ; FIXED HEAD DISC PD428A 01.00 (12) ; SELECTOR CHAN PD429A 01.01 (13) ; FLT.CORR.MEM SER-II PD430A 01.01 (14) ; FLT.CORR.MEM SER-III PD430B 00.00 (15) ; EXTEND INSTRUC SET PD431A 01.00 (16) ; HSI DIAG. PD432A 01.00 (17) ; MAGNETIC TAPE PD433A 01.04 (20) ; SSLC INTERFACE PD434A 01.03 (21) ; ASLC INTERFACE PD434B 01.04 (22) ; UI DIAG PD435A 01.01 (23) ; TERMINAL CONTROL PD438A 01.00 (24) ; CALCOMP PLOTTER PD439A 01.01 (25) ; COBOLII A F/W DIAG PD441A 00.00 (26) ; COBOLII B F/W DIAG PD442A 00.00 (27) ; STAND ALONE DISC SADUTIL 01.00 (30) deposit SWCH 3 ; Run and configure the diagnostic. echo echo Loading the diagnostic. echo Expect halt 16 if successful. go ; Verify HALT 16 to set the switch register options. assert CIR=030376 echo echo Configuring the diagnostic. ; Set the Switch Register options: ; ; + bit 0 = select the external switch register ; bit 1 = modify the Section Select Register ; bit 2 = not used ; bit 3 = not used ; bit 4 = not used ; bit 5 = channel selection (0/1 = automatic/manual) ; bit 6 = not used ; bit 7 = not used ; bit 8 = not used ; bit 9 = not used ; bit 10 = not used ; bit 11 = loop on the last step ; + bit 12 = halt on error ; bit 13 = halt at the end of each step ; bit 14 = halt at the end of each section ; + bit 15 = halt at the end of each diagnostic pass deposit SWCH 100011 ; Start the diagnostic. echo echo Executing the diagnostic. echo Expect message "PASS # 000000" and halt 15 if successful. reply "\r" ; Respond to "LOW BANK?" go until "?" ; reply "0\r" ; Respond to "LOW ADDRESS?" go until "?" ; reply "020000\r" ; Respond to "HIGH BANK?" go until "?" ; reply "3\r" ; Respond to "HIGH ADDRESS?" go until "?" ; reply "177777\r" go ; End the of diagnostic. ; ; Verify HALT 15 for a successful pass. assert CIR=030375