Logging to file "DIAG-SUITE.log" Run started on Jul 19, 2024 at 01:53:49 HP 3000 simulator V3.12-5.2 Release 13 delta 6 [32b data, 32b addresses, no Ethernet] Configuring the simulation environment. ------------------------- HP 3000 Diagnostics Suite ------------------------- --------------------- D420A - CPU Section 1 --------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Configuring the diagnostic. Executing the diagnostic. Expect pause 0 if successful. CPU paused, P: 010000 (PAUS 0) Continuing the diagnostic. Expect halt 6 if successful. Programmed halt, CIR: 030366 (HALT 6), P: 010415 (LDI 2) Verifying the SR register and continuing the diagnostic. Expect halt 7 if successful. Programmed halt, CIR: 030367 (HALT 7), P: 010422 (SETR) Verifying the SR register and continuing the diagnostic. Expect halt 10 if successful. Programmed halt, CIR: 030370 (HALT 10), P: 010424 (LOAD DB+1) Verifying the SR register and continuing the diagnostic. Expect halt 11 if successful. Programmed halt, CIR: 030371 (HALT 11), P: 010017 (LOAD DB+1) Verifying the PB/P/PL registers and continuing the diagnostic. Expect halt 3 if successful. Programmed halt, CIR: 030363 (HALT 3), P: 026170 (RSW) Setting all even SWCH register switches and continuing the diagnostic. Expect halt 4 if successful. Programmed halt, CIR: 030364 (HALT 4), P: 026201 (RSW) Setting all odd SWCH register switches and continuing the diagnostic. Expect halt 5 if successful. Programmed halt, CIR: 030365 (HALT 5), P: 026212 (RSW) Restoring the switch register and continuing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 016250 (ZERO,NOP) ---------------------- D420A1 - CPU Section 2 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Configuring the diagnostic. Executing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010141 (LOAD DB+0) ---------------------- D420A2 - CPU Section 3 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Configuring the diagnostic. Executing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010163 (ZERO,NOP) ---------------------- D420A3 - CPU Section 4 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Configuring the diagnostic. Starting the diagnostic. Expect a PAUS instruction stop if successful. CPU paused, P: 021376 (PAUS 12) Verifying the CIR register and continuing with a power failure. Expect halt 14 if successful. Programmed halt, CIR: 030374 (HALT 14), P: 011130 (EXIT 0) Verifying the CIR register and continuing with a power restoration. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010630 (ZERO,NOP) ---------------------- D420A4 - CPU Section 5 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Configuring the diagnostic. Executing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010607 (ZERO,NOP) ---------------------- D420A5 - CPU Section 6 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 3 for successful completion. System halt 3, P: 010011 (SETR STATUS) ---------------------- D420A6 - CPU Section 7 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 33 for successful completion. System halt 33, P: 010011 (SETR STATUS) ---------------------- D420A7 - CPU Section 8 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 5 for successful completion. System halt 5, P: 010014 (PCAL 0) ---------------------- D420A8 - CPU Section 9 ---------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 2 for successful completion. System halt 2, P: 010016 (PCAL 0) ----------------------- D420A9 - CPU Section 10 ----------------------- Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 6 for successful completion. System halt 6, P: 010052 (IXIT) ------------------------ D420A10 - CPU Section 11 ------------------------ Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 9 for successful completion. System halt 9, P: 010011 (PSEB) ------------------------ D420A11 - CPU Section 12 ------------------------ Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 1 for successful completion. System halt 1, P: 010005 (SETR STATUS) ------------------------ D420A12 - CPU Section 13 ------------------------ Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 4 for successful completion. System halt 4, P: 010010 (ADDS 0) ------------------------ D420A13 - CPU Section 14 ------------------------ Loading the diagnostic. Cold load complete, P: 001231 (LOAD P+14) Executing the diagnostic. Expect a system halt 4 for successful completion. System halt 4, P: 010003 (LDI 0) ---------------------------------------------------- D431A - Extended Instruction Set Firmware Diagnostic ---------------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 6 if successful. D01 HP30012A EXTENDED-INSTRUCTION SET DIAGNOSTIC (D431.01.00) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. Q01 SELECT SWREG OPTIONS Programmed halt, CIR: 030366 (HALT 6), P: 010117 (RSW) Configuring the switch register. Expect halt 5 if successful. Q02 SELECT SECTION SWREG. OPTIONS Programmed halt, CIR: 030365 (HALT 5), P: 010165 (RSW) Configuring the section select register. Expect halt 7 if successful. Q03 RESTORE SWREG OPTIONS Programmed halt, CIR: 030367 (HALT 7), P: 010203 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Q04 ENTER MAXIMUM ERROR COUNT# = 50 Q05 ENTER PASS NUMBER =1 D02 1 PASS COMPLETED Programmed halt, CIR: 030375 (HALT 15), P: 046030 (BR P+1,I) -------------------------------------- D441A - COBOL-II A Firmware Diagnostic -------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. COBOLIIA F/W DIAG. (D441A.00.00) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. TESTING MFL OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MFL OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING MC'N OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MCN OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING IC AND SUFT OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 IC OF EDIT PASSED ALL TESTS WITHOUT ERROR SUFT OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING MA'N OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MA OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING ICS AND SST0 AND SST1 OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 ICS OF EDIT PASSED ALL TESTS WITHOUT ERROR SST0 OF EDIT PASSED ALL TESTS WITHOUT ERROR SST1 OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING ICI OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 ICI OF EDIT PASSED ALL TESTS WITHOUT ERROR BRIS OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING MN'N OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MN OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING SFC AND ICSI OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 SFC OF EDIT PASSED ALL TESTS WITHOUT ERROR ICSI OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING MNS OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MNS OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING DBNZ AND SETC OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 DBNZ OF EDIT PASSED ALL TESTS WITHOUT ERROR SETC OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING MDWO AND SUFS OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 MDWO OF EDIT PASSED ALL TESTS WITHOUT ERROR SUFS OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING ICP OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 ICP OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING ICPS OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 ICPS OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING "IS" OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 "IS" OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** TESTING "ENDF" OF EDIT TESTING "SFLC" OF EDIT TESTING "DFLC" OF EDIT PB'DB'MODE= 0 PB'DB'MODE= 1 "ENDF" OF EDIT PASSED ALL TESTS WITHOUT ERROR "SFLC" OF EDIT PASSED ALL TESTS WITHOUT ERROR "DFLC" OF EDIT PASSED ALL TESTS WITHOUT ERROR ******************************************************************************** END OF PASS 0 Programmed halt, CIR: 030375 (HALT 15), P: 010330 (RSW) -------------------------------------- D442A - COBOL-II B Firmware Diagnostic -------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. COBOLIIB FIRMWARE DIAGNOSTIC (D442A.00.00) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. TESTING ABSD ABSD PASSED ALL TESTS WITHOUT ERROR TESTING ABSN ABSN PASSED ALL TESTS WITHOUT ERROR TESTING XBR XBR PASSED ALL TESTS WITHOUT ERROR TESTING NEGD SDEC= 0 SDEC= 1 NEGD PASSED ALL TESTS WITHOUT ERROR TESTING PARC AND ENDP I AM IN OUTER'BLOCK OF PARC I AM IN PAR6 I AM IN OUTER'BLOCK OF PARC PARC AND ENDP PASSED ALL TESTS WITHOUT ERROR TESTING TR TESTING DB TABLE ACCESS TESTING PB TABLE ACCESS TR PASSED ALL TESTS WITHOUT ERROR TESTING CVND SDEC = 0 SDEC = 1 CVND PASSED ALL TESTS WITHOUT ERROR TESTING CMPS TESTING DB-TARGET ACCESS TESTING PB-TARGET ACCESS CMPS PASSED ALL TESTS WITHOUT ERROR TESTING CMPT TESTING TRANSLATION TABLE IN PB TESTING DB-TARGET ACCESS TESTING PB-TARGET ACCESS CMPT PASSED ALL TESTS WITHOUT ERRORS TESTING TCCS TCCS PASSED ALL TESTS WITHOUT ERROR TESTING LDW SDEC=0 SDEC=1 TESTING LDDW SDEC=0 SDEC=1 LDW AND LDWW PASSED ALL TESTS WITHOUT ERROR TESTING ALGN ALGN PASSED ALL TESTS WITHOUT ERROR END OF PASS 0 Programmed halt, CIR: 030375 (HALT 15), P: 010315 (RSW) ------------------------------- D427A - Terminal Data Interface ------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 6 if successful. Programmed halt, CIR: 030366 (HALT 6), P: 010764 (LRA P+4) Configuring the switch register. Expect halt 5 if successful. Programmed halt, CIR: 030365 (HALT 5), P: 010215 (RSW) Configuring the section select register. Expect halt 6 if successful. Programmed halt, CIR: 030366 (HALT 6), P: 010231 (BR P-47) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010331 (BR P+7) ---------------------------------- D438A - Terminal Control Interface ---------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 6 if successful. Programmed halt, CIR: 030366 (HALT 6), P: 010670 (LRA P+4) Configuring the switch register. Expect halt 5 if successful. Programmed halt, CIR: 030365 (HALT 5), P: 010073 (RSW) Configuring the section select register. Expect halt 6 if successful. Programmed halt, CIR: 030366 (HALT 6), P: 010107 (BR P-47) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Programmed halt, CIR: 030375 (HALT 15), P: 010225 (BR P+7) -------------------------- D421 - Memory Pattern Test -------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 16 if successful. Programmed halt, CIR: 030376 (HALT 16), P: 015056 (RSW) Configuring the diagnostic. Executing the diagnostic. Expect message "PASS # 000000" and halt 15 if successful. HP 3000 SERIES II MEMORY PATERN TEST D421A.01.0 (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. LOW BANK?0 LOW ADDRESS?020000 HIGH BANK?3 HIGH ADDRESS?177777 PASS # 000000 Programmed halt, CIR: 030375 (HALT 15), P: 010255 (BR P-154) ------------------------------------------ D429A - Selector Channel Maintenance Board ------------------------------------------ Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 0 if successful. D100 HP30030B/C SELECTOR CHANNEL DIAG (D429A.01.01) (C)COPYRIGHT HEWLETT-PACKARD COMPANY 1978. Q104 SELECT OPTIONS Programmed halt, CIR: 030360 (HALT 0), P: 010033 (RSW) Configuring the switch register. Expect halt 1 if successful. Q110 SELECT SECTION OPTIONS Programmed halt, CIR: 030361 (HALT 1), P: 010073 (RSW) Configuring the section select register. Expect halt 2 if successful. Q111 RESTORE SELECT OPTIONS Programmed halt, CIR: 030362 (HALT 2), P: 010102 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for a successful first pass. Q101 SET MAINT CARD DEV NUM? 65 Q102 SET TIMER/CONSOLE DEV NUM? 3 Q108 ENTER UPPER BANK # (DECIMAL) = 7 Q105 ERR PRINT LIMIT? 999 D110 DIRECT I/O TEST D127 DIRECT I/O TEST COMPLETED D130 CONTROL ORDER TEST D217 CONTROL ORDER TEST COMPLETE D220 READ TEST D244 2K READ 4 MILLISEC; BANK00 D244 2K READ 4 MILLISEC; BANK01 D244 2K READ 4 MILLISEC; BANK02 D244 2K READ 4 MILLISEC; BANK03 D244 2K READ 4 MILLISEC; BANK04 D244 2K READ 4 MILLISEC; BANK05 D244 2K READ 4 MILLISEC; BANK06 D244 2K READ 4 MILLISEC; BANK07 D247 READ TEST COMPLETED D250 WRITE TEST D274 2K WRITE 4 MILLISEC; BANK00 D274 2K WRITE 4 MILLISEC; BANK01 D274 2K WRITE 4 MILLISEC; BANK02 D274 2K WRITE 4 MILLISEC; BANK03 D274 2K WRITE 4 MILLISEC; BANK04 D274 2K WRITE 4 MILLISEC; BANK05 D274 2K WRITE 4 MILLISEC; BANK06 D274 2K WRITE 4 MILLISEC; BANK07 D275 WRITE TEST COMPLETED D300 CHAINED READ TEST D317 CHAINED READ TEST COMPLETED D320 CHAINED WRITE TEST D337 CHAINED WRITE TEST COMPLETE D340 ERROR RESPONSE TEST D367 ERROR RESPONSE TEST COMPLETED D600 SELECTOR CHANNEL DIAG COMPLETE D601 END OF PASS 1 Programmed halt, CIR: 030375 (HALT 15), P: 010427 (SED 0) Configuring the switch register. Expect halt 1 if successful. D600 SELECTOR CHANNEL DIAG COMPLETE D601 END OF PASS 2 Q110 SELECT SECTION OPTIONS Programmed halt, CIR: 030361 (HALT 1), P: 010073 (RSW) Configuring the section select register. Expect halt 2 if successful. Q111 RESTORE SELECT OPTIONS Programmed halt, CIR: 030362 (HALT 2), P: 010102 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Q101 SET MAINT CARD DEV NUM? 66 Q102 SET TIMER/CONSOLE DEV NUM? 3 Q108 ENTER UPPER BANK # (DECIMAL) = 7 Q105 ERR PRINT LIMIT? 999 D110 DIRECT I/O TEST D127 DIRECT I/O TEST COMPLETED D130 CONTROL ORDER TEST D217 CONTROL ORDER TEST COMPLETE D220 READ TEST D244 2K READ 4 MILLISEC; BANK00 D244 2K READ 4 MILLISEC; BANK01 D244 2K READ 4 MILLISEC; BANK02 D244 2K READ 4 MILLISEC; BANK03 D244 2K READ 4 MILLISEC; BANK04 D244 2K READ 4 MILLISEC; BANK05 D244 2K READ 4 MILLISEC; BANK06 D244 2K READ 4 MILLISEC; BANK07 D247 READ TEST COMPLETED D250 WRITE TEST D274 2K WRITE 4 MILLISEC; BANK00 D274 2K WRITE 4 MILLISEC; BANK01 D274 2K WRITE 4 MILLISEC; BANK02 D274 2K WRITE 4 MILLISEC; BANK03 D274 2K WRITE 4 MILLISEC; BANK04 D274 2K WRITE 4 MILLISEC; BANK05 D274 2K WRITE 4 MILLISEC; BANK06 D274 2K WRITE 4 MILLISEC; BANK07 D275 WRITE TEST COMPLETED D300 CHAINED READ TEST D317 CHAINED READ TEST COMPLETED D320 CHAINED WRITE TEST D337 CHAINED WRITE TEST COMPLETE D340 ERROR RESPONSE TEST D367 ERROR RESPONSE TEST COMPLETED D600 SELECTOR CHANNEL DIAG COMPLETE D601 END OF PASS 1 Programmed halt, CIR: 030375 (HALT 15), P: 010427 (SED 0) ------------------------ D429A - Selector Channel ------------------------ Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 0 if successful. D100 HP30030B/C SELECTOR CHANNEL DIAG (D429A.01.01) (C)COPYRIGHT HEWLETT-PACKARD COMPANY 1978. Q104 SELECT OPTIONS Programmed halt, CIR: 030360 (HALT 0), P: 010033 (RSW) Configuring the switch register. Expect halt 1 if successful. Q110 SELECT SECTION OPTIONS Programmed halt, CIR: 030361 (HALT 1), P: 010073 (RSW) Configuring the section select register. Expect halt 2 if successful. Q111 RESTORE SELECT OPTIONS Programmed halt, CIR: 030362 (HALT 2), P: 010102 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Q101 SET MAINT CARD DEV NUM? 65 Q102 SET TIMER/CONSOLE DEV NUM? 3 Q108 ENTER UPPER BANK # (DECIMAL) = 7 Q105 ERR PRINT LIMIT? 999 D110 DIRECT I/O TEST D127 DIRECT I/O TEST COMPLETED D130 CONTROL ORDER TEST D217 CONTROL ORDER TEST COMPLETE D220 READ TEST D244 2K READ 1 MILLISEC; BANK00 D244 2K READ 1 MILLISEC; BANK01 D244 2K READ 1 MILLISEC; BANK02 D244 2K READ 1 MILLISEC; BANK03 D244 2K READ 1 MILLISEC; BANK04 D244 2K READ 1 MILLISEC; BANK05 D244 2K READ 1 MILLISEC; BANK06 D244 2K READ 1 MILLISEC; BANK07 D247 READ TEST COMPLETED D250 WRITE TEST D274 2K WRITE 1 MILLISEC; BANK00 D274 2K WRITE 1 MILLISEC; BANK01 D274 2K WRITE 1 MILLISEC; BANK02 D274 2K WRITE 1 MILLISEC; BANK03 D274 2K WRITE 1 MILLISEC; BANK04 D274 2K WRITE 1 MILLISEC; BANK05 D274 2K WRITE 1 MILLISEC; BANK06 D274 2K WRITE 1 MILLISEC; BANK07 D275 WRITE TEST COMPLETED D300 CHAINED READ TEST D317 CHAINED READ TEST COMPLETED D320 CHAINED WRITE TEST D337 CHAINED WRITE TEST COMPLETE D340 ERROR RESPONSE TEST D367 ERROR RESPONSE TEST COMPLETED D600 SELECTOR CHANNEL DIAG COMPLETE D601 END OF PASS 1 Programmed halt, CIR: 030375 (HALT 15), P: 010427 (SED 0) --------------------------- D422A - Multiplexer Channel --------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 0 if successful. DO1 30036A/B MPX CHANNEL TEST (HP D422A.01.2) (C)COPYRIGHT HEWLETT-PACKARD COMPANY 1978. Q01 SELECT SWITCH REGISTER OPTIONS Programmed halt, CIR: 030360 (HALT 0), P: 042614 (RSW) Configuring the switch register. Expect halt 1 if successful. Q02 SELECT SECTION OPTIONS Programmed halt, CIR: 030361 (HALT 1), P: 042660 (LDI 1) Configuring the section select register. Expect halt 2 if successful. Q03 RESTORE REGISTER OPTIONS Programmed halt, CIR: 030362 (HALT 2), P: 042667 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. Q04 ENTER MPX DEVICE #= 127 Q05 ENTER MAXIMUM ERROR COUNT# = 999 P02 END SECTION IORES P02 END SECTION ARADDR P02 END SECTION ARDATA P02 END SECTION ARCPP P02 END SECTION ORADDR P02 END SECTION ORDATA P02 END SECTION ORCP P02 END SECTION AREG P02 END SECTION OREG P02 END SECTION NSGP1 P02 END SECTION NSGP2 P02 END SECTION NSGP3 P02 END SECTION NSGP4 P02 END SECTION STPAR P11 IF SEL. CHAN. MAINTENANCE BOARD ALREADY IN THEN HIT * CR* P11 OTHERWISE INSERT BOARD,CONNECT POLLS,AND RE-COLD LOAD Q06 ENTER SEL. CHAN. MAINTENANCE BOARD DRT# =65 Q07 ENTER 2ND SCMB DRT# = 66 Q08 ENTER CLOCK/CONSOLE DRT# = 3 Q09 ENTER UPPER BANK # (DECIMAL) = 7 P15 END SIO TEST CONFIGURATION P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 00; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 01; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 02; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 03; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 04; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 05; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 06; STEP 63 P16 FAST SR READ MODE(2K XFER); TIME = 4 MSEC.; BANK 07; STEP 63 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 00; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 01; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 02; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 03; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 04; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 05; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 06; STEP 68 P17 FAST SR WRITE MODE(2K XFER); TIME=4 MSEC.; BANK 07; STEP 68 P02 END SECTION SIOTST D02 END MPX CHAN TEST D03 END: PROGRAM CYCLE: PASS = 1 Programmed halt, CIR: 030375 (HALT 15), P: 010175 (ZERO,NOP) -------------------------------------------- D426A - System Clock/Fault Logging Interface -------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading the diagnostic. Expect halt 0 if successful. D01 HP SYSTEM CLOCK DIAGNOSTIC (D426A.00.00) (C)COPYRIGHT HEWLETT-PACKARD COMPANY 1978. Q02 SELECT SWREG OPTIONS Programmed halt, CIR: 030360 (HALT 0), P: 010022 (RSW) Configuring the switch register. Expect halt 1 if successful. Q03 SELECT SECTION SWREG. OPTIONS Programmed halt, CIR: 030361 (HALT 1), P: 010066 (RSW) Configuring the section select register. Expect halt 2 if successful. Q05 RESTORE SWREG OPTIONS Programmed halt, CIR: 030362 (HALT 2), P: 010075 (RSW) Reconfiguring the switch register and executing the diagnostic. Expect halt 15 for successful completion. P01 SECTION 1 P03 END STEP 101 P03 END STEP 103 P03 END STEP 105 P02 END SECTION 1 P01 SECTION 2 P03 END STEP 202 P03 END STEP 203 P03 END STEP 204 P03 END STEP 205 P03 END STEP 206 P03 END STEP 207 P03 END STEP 210 P02 END SECTION 2 P01 SECTION 3 P03 END STEP 302 P03 END STEP 304 P03 END STEP 306 P03 END STEP 310 P03 END STEP 312 P03 END STEP 314 P03 END STEP 316 P02 END SECTION 3 P01 SECTION 4 P03 END STEP 402 P03 END STEP 404 P03 END STEP 406 P03 END STEP 407 P03 END STEP 410 P03 END STEP 411 P03 END STEP 412 P03 END STEP 413 P03 END STEP 414 P03 END STEP 415 P03 END STEP 422 P03 END STEP 424 P03 END STEP 426 P02 END SECTION 4 D02 END: PROGRAM CYCLE: PASS = 1 D03 HALT: COMPLETE PROGRAM CYCLE Programmed halt, CIR: 030375 (HALT 15), P: 010300 (BR P-230) ----------------------------------------- D419A - Cartridge Disc (user interaction) ----------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. D99 01 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC CONFIGURATION (D419A.01.4) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. Q99 02 DECIMAL DEVICE NUMBER? 4 Q99 03 MAXIMUM ERROR PRINT COUNT? 999 P99 55 UPDATE SWITCH REGISTER sim> deposit SWCH 140000 sim> go Q99 61 RESTART?(YES/NO) NO Q99 06 PRESENT SECTION REGISTER: %177000 DO YOU WISH TO CHANGE?(YES/NO) YES Q99 06 UPDATE SECTION REGISTER: % 177002 Q99 06 PRESENT SECTION REGISTER: %177002 DO YOU WISH TO CHANGE?(YES/NO) NO P99 51 RESET SWITCH 1 (CHANGE) sim> deposit SWCH 100001 sim> go P99 05 RESET BOTH PROT.DATA SWITCHES,SET SWITCH FORMAT AND SET UNIT TO 0 Q99 42 WISH TO EXECUTE INTERACTIVE PORTION IN SECTION 1 (YES/NO) YES D99 07 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC OFF-LINE (D419A.01.4) Q18 68 DO YOU WISH FORMAT DISC? (YES/NO) NO P19 19 SET UPPER DATA PROTECT SWITCH sim> set DS0 PROTECT=UPPER sim> go P19 27 RESET SWITCH FORMAT sim> set DS0 NOFORMAT sim> go P19 19 RESET UPPER DATA PROTECT SWITCH sim> set DS0 UNPROTECT=UPPER sim> go P19 20 SET LOWER DATA PROTECT SWITCH sim> set DS0 PROTECT=LOWER sim> go P19 26 SET SWITCH FORMAT sim> set DS0 FORMAT sim> go P19 19 SET UPPER DATA PROTECT SWITCH sim> set DS0 PROTECT=UPPER sim> go P19 27 RESET SWITCH FORMAT sim> set DS0 NOFORMAT sim> go P19 05 RESET BOTH PROT.DATA SWITCHES,SET SWITCH FORMAT sim> set DS0 UNPROTECT sim> set DS0 FORMAT sim> go P20 58 RESET RUN SWITCH AT UNIT 0 sim> set DS0 UNLOAD sim> go P20 58 SET RUN SWITCH AND WAIT UNTIL READY sim> set DS0 LOAD sim> go D92 57 SHORT PASS 0001 CYL: HEAD0% HEAD1% HEAD2% (ERROR TABLES) UNIT0 UNIT1 UNIT2 UNIT3 UNIT4 UNIT5 UNIT6 UNIT7 0000 0000 0000 0000 0000 0000 0000 0000 P92 47 PAUSE AT PASS 000001 -------------------------------------------------- D419A - Cartridge Disc (multiple unit, short pass) -------------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. D99 01 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC CONFIGURATION (D419A.01.4) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. Q99 02 DECIMAL DEVICE NUMBER? 4 Q99 03 MAXIMUM ERROR PRINT COUNT? 999 P99 55 UPDATE SWITCH REGISTER sim> deposit SWCH 140000 sim> go Q99 61 RESTART?(YES/NO) NO Q99 06 PRESENT SECTION REGISTER: %177000 DO YOU WISH TO CHANGE?(YES/NO) YES Q99 06 UPDATE SECTION REGISTER: % 137402 Q99 06 PRESENT SECTION REGISTER: %137402 DO YOU WISH TO CHANGE?(YES/NO) NO P99 08 UNIT NUMBER TABLE 01 DRIVE(S);00 Q99 09 WISH TO ALTER TABLE? YES Q99 10 ENTER UNIT NUMBERS SEPARATED BY COMMAS 0,1,2,3,4,5,6,7 P99 08 UNIT NUMBER TABLE 08 DRIVE(S);00 01 02 03 04 05 06 07 Q99 09 WISH TO ALTER TABLE? NO P99 51 RESET SWITCH 1 (CHANGE) sim> deposit SWCH 100001 sim> go P99 05 RESET BOTH PROT.DATA SWITCHES,SET SWITCH FORMAT AND SET UNIT TO 0 Q99 42 WISH TO EXECUTE INTERACTIVE PORTION IN SECTION 1 (YES/NO) NO D99 07 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC OFF-LINE (D419A.01.4) D92 57 SHORT PASS 0001 CYL: HEAD0% HEAD1% HEAD2% (ERROR TABLES) UNIT0 UNIT1 UNIT2 UNIT3 UNIT4 UNIT5 UNIT6 UNIT7 0000 0000 0000 0000 0000 0000 0000 0000 P92 47 PAUSE AT PASS 000001 ------------------------------------------------- D419A - Cartridge Disc (multiple unit, long pass) ------------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. D99 01 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC CONFIGURATION (D419A.01.4) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. Q99 02 DECIMAL DEVICE NUMBER? 4 Q99 03 MAXIMUM ERROR PRINT COUNT? 999 P99 55 UPDATE SWITCH REGISTER sim> deposit SWCH 140000 sim> go Q99 61 RESTART?(YES/NO) NO Q99 06 PRESENT SECTION REGISTER: %177000 DO YOU WISH TO CHANGE?(YES/NO) YES Q99 06 UPDATE SECTION REGISTER: % 137400 Q99 06 PRESENT SECTION REGISTER: %137400 DO YOU WISH TO CHANGE?(YES/NO) NO P99 08 UNIT NUMBER TABLE 01 DRIVE(S);00 Q99 09 WISH TO ALTER TABLE? YES Q99 10 ENTER UNIT NUMBERS SEPARATED BY COMMAS 0,1 P99 08 UNIT NUMBER TABLE 02 DRIVE(S);00 01 Q99 09 WISH TO ALTER TABLE? NO P99 51 RESET SWITCH 1 (CHANGE) sim> deposit SWCH 100001 sim> go P99 05 RESET BOTH PROT.DATA SWITCHES,SET SWITCH FORMAT AND SET UNIT TO 0 Q99 42 WISH TO EXECUTE INTERACTIVE PORTION IN SECTION 1 (YES/NO) NO D99 07 CARTRIDGE DISC (HP 30129A) DIAGNOSTIC OFF-LINE (D419A.01.4) D92 56 LONG PASS 0001 CYL: HEAD0% HEAD1% HEAD2% (ERROR TABLES) UNIT0 UNIT1 UNIT2 UNIT3 UNIT4 UNIT5 UNIT6 UNIT7 0000 0000 0000 0000 0000 0000 0000 0000 P92 47 PAUSE AT PASS 000001 --------------------------------------------------------- D433A - 7970E Nine-Track Magnetic Tape (user interaction) --------------------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. HP 30115A 9-TRACK MAGNETIC TAPE (D433A.01.4) (STAND-ALONE DIAGNOSTIC PROGRAM) (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1976. Q010 TAPE DEVICE NUMBER? 6 Q011 TIMER DEVICE NUMBER? 3 Q012 MAXIMUM ERROR PRINT COUNT? 100 P005 TYPE FOLLOWING CONTROL A'CR'-AUTO, R'CR'-RESTART, M'CR'-MANU, 'CR'-RESUME, YOUR CODE? M D015 PRESENT SECTION REGISTER:%077414 DO YOU WISH TO CHANGE?(YES/NO)YES D015 UPDATE SECTION REGISTER:%000014 D015 PRESENT SECTION REGISTER:%000014 DO YOU WISH TO CHANGE?(YES/NO)NO P015 MANU PROCES: UPDATE SWITCH REGISTER (CR) NEW INT.SW.REG 1 000 000 000 001 001 P019 ON-LINE/RESET TEST P026 LOAD TAPE(RING), PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> attach -n MS0 SCRATCH.TAPE sim> set MS0 OFFLINE sim> go P027 PUSH DRIVE 0, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P027 PUSH DRIVE 1, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> go P027 PUSH DRIVE 2, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> go P027 PUSH DRIVE 3, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND P056 TYPE SELECTED DRIVE ? sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go 0 P038 PUSH DRIVE 0 BUTTON & TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P039 CHECK LIGHT RESET, PUSH ON-LINE AND RESPOND sim> set MS0 ONLINE sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 0 AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 1 AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 2 AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 3 AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P032 PUSH DRIVE 0 AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> set MS0 ONLINE sim> go P032 PUSH DRIVE 1 AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> set MS1 ONLINE sim> go P032 PUSH DRIVE 2 AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> set MS2 ONLINE sim> go P032 PUSH DRIVE 3 AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> set MS3 ONLINE sim> go P034 PUT TAPE(RING), PUSH OFF, RESET AND RESPOND 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 0 AND TAPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 1 AND TAPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 2 AND TAPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 3 AND TAPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> go P037 FSR/BSR-TEST: TYPE DRIVE NUMBER AND 'CR'(EXECUTE) OR 'CR'(EXIT)0 P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 0 AND TAPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go [This test takes a long time.] D031 TEST SECTION M12 COMPL. P056 TYPE SELECTED DRIVE ? 0 P041 LOAD TAPE(RING), PUSH DRIVE 0 AND TYPE RESPONSE 'CR sim> attach -n MS0 scratch.tape sim> go P042 REMOVE RING FROM REEL, PUT IT BACK AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach -r MS0 scratch.tape sim> go P043 PUT RING BACK TO REEL, LOAD IT AND TYPE 'CR'(RESPONSE) sim> detach MS0 sim> attach MS0 scratch.tape sim> go D031 TEST SECTION M13 COMPL. P060 01 PASS 000000 TOTAL ERRORS P010 PAUSE AT PASS 01 ------------------------------------------------------ D433A - 7970E Nine-Track Magnetic Tape (multiple unit) ------------------------------------------------------ Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. HP 30115A 9-TRACK MAGNETIC TAPE (D433A.01.4) (STAND-ALONE DIAGNOSTIC PROGRAM) (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1976. Q010 TAPE DEVICE NUMBER? 6 Q011 TIMER DEVICE NUMBER? 3 Q012 MAXIMUM ERROR PRINT COUNT? 100 P005 TYPE FOLLOWING CONTROL A'CR'-AUTO, R'CR'-RESTART, M'CR'-MANU, 'CR'-RESUME, YOUR CODE? A D015 PRESENT SECTION REGISTER:%077414 DO YOU WISH TO CHANGE?(YES/NO)YES D015 UPDATE SECTION REGISTER:%077400 D015 PRESENT SECTION REGISTER:%077400 DO YOU WISH TO CHANGE?(YES/NO)NO Q019 AUTO-PROCESS: ENTER TAPE UNIT(B,E,NO) AT Q020 DRIVE 0? E Q020 DRIVE 1? E Q020 DRIVE 2? E Q020 DRIVE 3? E P003 UNLOAD PROGRAM TAPE - LOAD TEST TAPE(S) Q030 ALL DEFINITIONS CORRECT(YES/NO)? YES P011 UPDATE SWITCH REGISTER (CR) NEW INT.SW.REG 1 000 000 000 001 001 D031 TEST SECTION A01 COMPL. D031 TEST SECTION A02 COMPL. D031 TEST SECTION A03 COMPL. D031 TEST SECTION A04 COMPL. D031 TEST SECTION A05 COMPL. D031 TEST SECTION A06 COMPL. D031 TEST SECTION A07 COMPL. P060 01 PASS 000000 TOTAL ERRORS P010 PAUSE AT PASS 01 --------------------------------------------------------- D433A - 7970B Nine-Track Magnetic Tape (user interaction) --------------------------------------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. HP 30115A 9-TRACK MAGNETIC TAPE (D433A.01.4) (STAND-ALONE DIAGNOSTIC PROGRAM) (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1976. Q010 TAPE DEVICE NUMBER? 6 Q011 TIMER DEVICE NUMBER? 3 Q012 MAXIMUM ERROR PRINT COUNT? 100 P005 TYPE FOLLOWING CONTROL A'CR'-AUTO, R'CR'-RESTART, M'CR'-MANU, 'CR'-RESUME, YOUR CODE? M D015 PRESENT SECTION REGISTER:%077414 DO YOU WISH TO CHANGE?(YES/NO)YES D015 UPDATE SECTION REGISTER:%000014 D015 PRESENT SECTION REGISTER:%000014 DO YOU WISH TO CHANGE?(YES/NO)NO P015 MANU PROCES: UPDATE SWITCH REGISTER (CR) NEW INT.SW.REG 1 000 000 000 001 001 P019 ON-LINE/RESET TEST P026 LOAD TAPE(RING), PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> attach -n MS0 SCRATCH.TAPE sim> set MS0 OFFLINE sim> go P027 PUSH DRIVE 0, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P027 PUSH DRIVE 1, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> go P027 PUSH DRIVE 2, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> go P027 PUSH DRIVE 3, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P028 PUSH RESET, OFF AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND P056 TYPE SELECTED DRIVE ? sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go 0 P038 PUSH DRIVE 0 BUTTON & TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P039 CHECK LIGHT RESET, PUSH ON-LINE AND RESPOND sim> set MS0 ONLINE sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 0 AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 1 AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 2 AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P030 CHECK LIGHT WRITE-ENABLE, PUSH DRIVE 3 AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P032 PUSH DRIVE 0 AND TYPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> set MS0 ONLINE sim> go P032 PUSH DRIVE 1 AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> set MS1 ONLINE sim> go P032 PUSH DRIVE 2 AND TYPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> set MS2 ONLINE sim> go P032 PUSH DRIVE 3 AND TYPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P033 PUSH RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> set MS3 ONLINE sim> go P034 PUT TAPE(RING), PUSH OFF, RESET AND RESPOND 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 0 AND TAPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 1 AND TAPE RESPONSE 'CR' sim> detach MS0 sim> attach MS1 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS1 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 2 AND TAPE RESPONSE 'CR' sim> detach MS1 sim> attach MS2 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS2 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 3 AND TAPE RESPONSE 'CR' sim> detach MS2 sim> attach MS3 scratch.tape sim> go P036 PUSH RESET AND TYPE RESPONSE 'CR' sim> set MS3 OFFLINE sim> go P037 FSR/BSR-TEST: TYPE DRIVE NUMBER AND 'CR'(EXECUTE) OR 'CR'(EXIT)0 P029 LOAD TAPE(RING), PUSH OFF,RESET, ON-LINE AND TYPE RESPONSE 'CR' sim> detach MS3 sim> attach MS0 scratch.tape sim> set MS0 OFFLINE sim> go P035 PUSH ON-LINE, DRIVE 0 AND TAPE RESPONSE 'CR' sim> set MS0 ONLINE sim> go [This test takes a long time.] D031 TEST SECTION M12 COMPL. P056 TYPE SELECTED DRIVE ? 0 P041 LOAD TAPE(RING), PUSH DRIVE 0 AND TYPE RESPONSE 'CR sim> attach -n MS0 scratch.tape sim> go P042 REMOVE RING FROM REEL, PUT IT BACK AND TYPE RESPONSE 'CR' sim> detach MS0 sim> attach -r MS0 scratch.tape sim> go P043 PUT RING BACK TO REEL, LOAD IT AND TYPE 'CR'(RESPONSE) sim> detach MS0 sim> attach MS0 scratch.tape sim> go D031 TEST SECTION M13 COMPL. P060 01 PASS 000000 TOTAL ERRORS P010 PAUSE AT PASS 01 ------------------------------------------------------ D433A - 7970B Nine-Track Magnetic Tape (multiple unit) ------------------------------------------------------ Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. HP 30115A 9-TRACK MAGNETIC TAPE (D433A.01.4) (STAND-ALONE DIAGNOSTIC PROGRAM) (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1976. Q010 TAPE DEVICE NUMBER? 6 Q011 TIMER DEVICE NUMBER? 3 Q012 MAXIMUM ERROR PRINT COUNT? 100 P005 TYPE FOLLOWING CONTROL A'CR'-AUTO, R'CR'-RESTART, M'CR'-MANU, 'CR'-RESUME, YOUR CODE? A D015 PRESENT SECTION REGISTER:%077414 DO YOU WISH TO CHANGE?(YES/NO)YES D015 UPDATE SECTION REGISTER:%067400 D015 PRESENT SECTION REGISTER:%067400 DO YOU WISH TO CHANGE?(YES/NO)NO Q019 AUTO-PROCESS: ENTER TAPE UNIT(B,E,NO) AT Q020 DRIVE 0? B Q020 DRIVE 1? B Q020 DRIVE 2? B Q020 DRIVE 3? B P003 UNLOAD PROGRAM TAPE - LOAD TEST TAPE(S) Q030 ALL DEFINITIONS CORRECT(YES/NO)? YES P011 UPDATE SWITCH REGISTER (CR) NEW INT.SW.REG 1 000 000 000 000 001 D031 TEST SECTION A01 COMPL. D031 TEST SECTION A02 COMPL. E274 STEP-0434 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0434 EXPECT.- OBTAIN. CRCC 120200 032400 E274 STEP-0437 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0437 EXPECT.- OBTAIN. CRCC 000310 032400 E274 STEP-0434 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0434 EXPECT.- OBTAIN. CRCC 120200 032400 E274 STEP-0437 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0437 EXPECT.- OBTAIN. CRCC 000310 032400 E274 STEP-0434 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0434 EXPECT.- OBTAIN. CRCC 120200 032400 E274 STEP-0437 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0437 EXPECT.- OBTAIN. CRCC 000310 032400 E274 STEP-0434 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0434 EXPECT.- OBTAIN. CRCC 120200 032400 E274 STEP-0437 COMP. AND READ CRCC ARE DIFFER. E116 STEP-0437 EXPECT.- OBTAIN. CRCC 000310 032400 D065 000020 ERRORS IN SECTION 04 D066 000020 TOTAL ERRORS D031 TEST SECTION A04 COMPL. D031 TEST SECTION A05 COMPL. D031 TEST SECTION A06 COMPL. D031 TEST SECTION A07 COMPL. P060 01 PASS 000020 TOTAL ERRORS P010 PAUSE AT PASS 01 --------------------------- D435A - Universal Interface --------------------------- Loading the stand-alone loader. Cold load complete, P: 001231 (LOAD P+14) Loading and executing the diagnostic. D100 UNIV. INTERFACE TEST (HP D435A.01.01) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. ****************** WARNING ****************** this diagnostic has tests which will produce error conditions on interface boards which have datecodes PRIOR TO 1504. Q110 DEVICE NUMBER? 14 Q112 INTERRUPT MASK? 8 Q113 NEGATIVE TRUE? NO Q114 CHANGE INTERNAL SWITCH REGISTER? ? YES P114 INTERNAL SWITCH REGISTER Programmed halt, CIR: 030366 (HALT 6), P: 026015 (DDEL,DDEL) Configuring the switch register. Q115 SECTION LIST? Q116 READER-PUNCH INTERFACE ? NO D102 END SECTION 0 D100 UNIV. INTERFACE TEST (HP D435A.01.01) (C)COPYRIGHT HEWLETT PACKARD COMPANY 1976. ****************** WARNING ****************** this diagnostic has tests which will produce error conditions on interface boards which have datecodes PRIOR TO 1504. P120 CONT6 ON, REST OFF Programmed halt, CIR: 030367 (HALT 7), P: 022145 (DDEL,DDEL) [Verifying control bits.] P120 CONT7 ON, REST OFF Programmed halt, CIR: 030367 (HALT 7), P: 022145 (DDEL,DDEL) P120 CONT8 ON, REST OFF Programmed halt, CIR: 030367 (HALT 7), P: 022145 (DDEL,DDEL) P120 CONT9 ON, REST OFF Programmed halt, CIR: 030367 (HALT 7), P: 022145 (DDEL,DDEL) P120 CONT10 ON, REST OFF Programmed halt, CIR: 030367 (HALT 7), P: 022145 (DDEL,DDEL) P121 JUMPER J2W1 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W2 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W3 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W4 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W5 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W6 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W7 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W8 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W9 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P121 JUMPER J2W10 LOW, REST HIGH Programmed halt, CIR: 030370 (HALT 10), P: 022056 (DDEL,DDEL) P122 DEVICE END ASSERTED Programmed halt, CIR: 030371 (HALT 11), P: 021505 (DDEL,DDEL) P124 BIT 0 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 1 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 2 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 3 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 4 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 5 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 6 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 7 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 8 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 9 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 10 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 11 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 12 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 13 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 14 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) P124 BIT 15 HIGH, REST LOW Programmed halt, CIR: 030373 (HALT 13), P: 021407 (DDEL,DDEL) D102 END SECTION 1 D102 END SECTION 2 D102 END SECTION 3 D102 END SECTION 4 D102 END SECTION 5 D102 END SECTION 6 D102 END SECTION 7 D102 END SECTION 8 D102 END SECTION 9 D102 END SECTION 10 P103 PASS 1 Programmed halt, CIR: 030375 (HALT 15), P: 010265 (DDEL,DDEL) ------------------------------ Diagnostics Suite Run Complete ------------------------------ Run ended on Jul 19, 2024 at 02:08:36 Goodbye Log file closed