Logging to file "DIAG-DUS.log" HP 3000 simulator V3.12-5.2 Release 13 delta 6 [32b data, 32b addresses, no Ethernet] Configuring the simulation environment. ------------------------------- Diagnostic Utility System Suite ------------------------------- Loading DUS. Cold load complete, P: 006770 (ADDS 11) Starting DUS. Diagnostic/Utility System Revision 03.06 Enter Your Program Name (type HELP for program information) : -------------------------------------------------------------- ADCCDIAG - Asynchronous Data Communications Channel Diagnostic -------------------------------------------------------------- Configuring the simulation environment. Starting the diagnostic (base PCA). :ADCCDIAG Asynchronous Data Communication Channel Diagnostic Revision 01.32 Type GO to continue (LC for List Commands) >TEST 1/15 >GO Replace ADCC cable(s) with test connector(s). What is the CHANNEL address of ADCC under test? 2 Is the extended ADCC present?(Y/N) N .................................................. .................................................. .................................................. .................................................. .................................................. ... ADCC Diagnostic Pass 0001 Replace test connector(s) with ADCC cable(s). Enter Your Program Name (type HELP for program information) : Starting the diagnostic (base and extender PCAs). :ADCCDIAG Asynchronous Data Communication Channel Diagnostic Revision 01.32 Type GO to continue (LC for List Commands) >TEST 1/15 >GO Replace ADCC cable(s) with test connector(s). What is the CHANNEL address of ADCC under test? 2 Is the extended ADCC present?(Y/N) Y .................................................. .................................................. .................................................. .................................................. .................................................. .................................................. .................................................. .................................................. .................................................. ....................................... ADCC Diagnostic Pass 0001 Replace test connector(s) with ADCC cable(s). Enter Your Program Name (type HELP for program information) : Starting the diagnostic (interactive). :ADCCDIAG Asynchronous Data Communication Channel Diagnostic Revision 01.32 Type GO to continue (LC for List Commands) >TEST 16 >GO How many channels of all types are there installed? 3 Set Thumbwheel of ADCC under test to channel 00 Respond GO >GO Set Thumbwheel of ADCC under test to channel 02 Respond GO >GO Set Thumbwheel of ADCC under test to channel 03 Respond GO >GO Set Thumbwheel of ADCC under test to channel 04 Respond GO >GO Set Thumbwheel of ADCC under test to channel 05 Respond GO >GO Set Thumbwheel of ADCC under test to channel 06 Respond GO >GO Set Thumbwheel of ADCC under test to channel 07 Respond GO >GO Set Thumbwheel of ADCC under test to channel 08 Respond GO >GO Set Thumbwheel of ADCC under test to channel 10 Respond GO >GO Set Thumbwheel of ADCC under test to channel 11 Respond GO >GO Set Thumbwheel of ADCC under test to channel 12 Respond GO >GO Set Thumbwheel of ADCC under test to channel 13 Respond GO >GO Set Thumbwheel of ADCC under test to channel 14 Respond GO >GO Set Thumbwheel of ADCC under test to channel 15 Respond GO >GO ADCC Diagnostic Pass 0001 Replace test connector(s) with ADCC cable(s). Enter Your Program Name (type HELP for program information) : ---------------------------------------- GICDIAG - General I/O Channel Diagnostic ---------------------------------------- Configuring the simulation environment. Starting the diagnostic. :GICDIAG GICDIAG 2.11 Enter 'GO' to continue. >SWITCHES >GO What is the GIC address (1-15)? 11 Please set all toggle switches to their outward positions. Enter 'GO' to continue. >GO Please set all toggle switches to their inward positions. Enter 'GO' to continue. >GO Please set SW4 to '12'. Enter 'GO' to continue. >GO Please set SW4 to '13'. Enter 'GO' to continue. >GO Please set SW4 to '14'. Enter 'GO' to continue. >GO Please set SW4 to '15'. Enter 'GO' to continue. >GO Please set SW4 to '2'. Enter 'GO' to continue. >GO Please set SW4 to '3'. Enter 'GO' to continue. >GO Please set SW4 to '4'. Enter 'GO' to continue. >GO Please set SW4 to '5'. Enter 'GO' to continue. >GO Please set SW4 to '6'. Enter 'GO' to continue. >GO Please set SW4 to '7'. Enter 'GO' to continue. >GO Please set SW4 to '8'. Enter 'GO' to continue. >GO Please set SW4 to '11'. Enter 'GO' to continue. >GO Register Test Error Log: bit 0 4 8 12 v v v v R3: .... .... .... .... R4: .... .... .... .... R5: .... .... .... .... R6: .... .... .... .... R7: .... .... .... .... Please set MODE switch (CHAN 11) to TEST, (OUT). Enter 'GO' to continue. >GO Measure HSE pulse at U151-4 or U151-12. High period should be 420-454 nanoseconds. Check R23 if timing is incorrect. Enter 'GO' to continue. >GO Select a second GIC, set its SYST CONT switch to OFF, and remove all its cables. Set the GIC under test's MODE switch to OPER and connect it to the second GIC with GIC cables. What is the second GIC address (1-15)? 10 GIC diagnostic pass 1. PASSED STEPS: 1,2,3,4,5,6,7,8,9,10,11,12,13,14,16,17,18,19,20,21,22,23,25, 26,27,28,29,30,31,32,33,34,35,36,37,39,40,41,42,43,44,45 Enter 'GO' to continue. >TEST 45 >RUN GICDIAG 2.11 Enter 'GO' to continue. >GO What is the GIC address (1-15)? 11 Select a second GIC, set its SYST CONT switch to OFF, and remove all its cables. Set the GIC under test's MODE switch to OPER and connect it to the second GIC with GIC cables. What is the second GIC address (1-15)? 12 GIC diagnostic pass 1. PASSED STEPS: 45 Enter 'GO' to continue. >EXIT Diagnostic/Utility System Revision 03.06 Enter Your Program Name (type HELP for program information) : -------------------------------------- D7970 - HP-IB 7970E Offline Diagnostic -------------------------------------- Configuring the simulation environment. Starting diagnostic sections 1-3. :AID AID 02.10 > 10 LOAD D7970S13 Program Loaded!! The Next Available Statement Number is >8290 7862 LET BADINTP:=0 >8290 RUN HP7970/HP-IB Mag Tape Diagnostic D7970S13 (01.03) 8/18/81 7970E channel number? 9 7970E device number? 1 Number of passes ? 1 Mount a tape with write ring on each unit to be tested. Set others offline, type go. >GO Unit 0 will be tested. Unit 1 will be tested. Unit 2 will be tested. Unit 3 will be tested. If OK type 0, else 1? 0 To output messages to: LP type 0, console 1? 1 Test Section 1 (Steps 100-117) is complete Step 220-Gapping to EOT. To abort this step, type a character, type GO 1 Step 220-Gapping to EOT. To abort this step, type a character, type GO 1 Step 220-Gapping to EOT. To abort this step, type a character, type GO 1 Step 220-Gapping to EOT. To abort this step, type a character, type GO 1 Test Section 2 (Steps 200-235) is complete Step 301 - PLEASE DON'T INTERRUPT Unit 0! This pause is part of test. Step 301 - PLEASE DON'T INTERRUPT Unit 1! This pause is part of test. Step 301 - PLEASE DON'T INTERRUPT Unit 2! This pause is part of test. Step 301 - PLEASE DON'T INTERRUPT Unit 3! This pause is part of test. Test Section 3 (Steps 300-305) is complete pass 1 Required 1 pass(es) complete > Starting diagnostic sections 4-5. >EXIT End of AID user program >8290 LOAD D7970S45 Confirm you want to ERASE the current program(Y or N)?YES Program Loaded!! The Next Available Statement Number is >7880 MODIFY 7435/7445 7435 FOR F:=0 STEP 20 UNTIL 1980 R7331 7331 FOR F:=0 STEP 20 UNTIL 1980 7440 ASSIGN BB(F),0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 R7332 7332 ASSIGN BB(F),0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 7445 NEXT 7435 R7333 7333 NEXT 7435 R7331 7333 NEXT 7331 >7880 RUN HP7970/HP-IB Mag Tape Diagnostic D7970S45 (01.03) 8/18/81 7970E channel number? 9 7970E device number? 1 Number of passes? 1 Mount a tape with write ring on each unit to be tested. Set others offline, type go. >GO Unit 0 will be tested. Unit 1 will be tested. Unit 2 will be tested. Unit 3 will be tested. If OK type 0, else 1? 0 To output messages to: LP type 0, console 1? 1 Test Section 4 (Steps 400-403) is complete. Test Section 5 (Tests 500-505) is complete pass 1 Required 1 pass(es) complete > Starting diagnostic sections 6 and 8. >EXIT End of AID user program >7880 LOAD D7970S68 Confirm you want to ERASE the current program(Y or N)?YES Program Loaded!! The Next Available Statement Number is >9710 RUN HP7970/HP-IB Mag Tape Diagnostic D7970S68 (01.02) 8/18/81 7970E channel number? 9 7970E device number? 1 SECTION 6 (Interactive). Enter: 0-Execute, 1-Skip ? 0 Put a magnetic tape with write ring onto unit under test and push LOAD, ON-LINE and UNIT#0 > sim> attach -N MAB0 scratch.0.tape sim> go >GO Reset any another tape unit connected to the same controller >GO Push RESET > sim> set MAB0 OFFLINE sim> go >GO Push ON-LINE > sim> set MAB0 ONLINE sim> go >GO Push UNIT 1 > sim> detach MAB0 sim> attach MAB1 scratch.0.tape sim> go >GO Push RESET > sim> set MAB1 OFFLINE sim> go >GO Push ON-LINE > sim> set MAB1 ONLINE sim> go >GO Push UNIT 2 > sim> detach MAB1 sim> attach MAB2 scratch.0.tape sim> go >GO Push RESET > sim> set MAB2 OFFLINE sim> go >GO Push ON-LINE > sim> set MAB2 ONLINE sim> go >GO Push UNIT 3 > sim> detach MAB2 sim> attach MAB3 scratch.0.tape sim> go >GO Push RESET > sim> set MAB3 OFFLINE sim> go >GO Push ON-LINE > sim> set MAB3 ONLINE sim> go >GO Push UNIT 0,1,2, and 3 > sim> detach MAB3 sim> attach MAB0 scratch.0.tape sim> detach MAB0 sim> attach MAB1 scratch.0.tape sim> detach MAB1 sim> attach MAB2 scratch.0.tape sim> detach MAB2 sim> attach MAB3 scratch.0.tape sim> go >GO Push UNIT 0 > sim> detach MAB3 sim> attach MAB0 scratch.0.tape sim> go >GO Push UNIT 1 > sim> detach MAB0 sim> attach MAB1 scratch.0.tape sim> go >GO Push UNIT 2 > sim> detach MAB1 sim> attach MAB2 scratch.0.tape sim> go >GO Push UNIT 3 > sim> detach MAB2 sim> attach MAB3 scratch.0.tape sim> go >GO Please remove write ring and remount tape. > sim> detach MAB3 sim> attach -R MAB3 scratch.0.tape sim> go >GO Check if RESET light is ON! Then: Put tape with write ring onto drive, and push LOAD, ON-LINE and UNIT 0 > sim> detach MAB3 sim> attach MAB0 scratch.0.tape sim> go >GO Is tested Unit#0 MASTER? (Y/N) ? Y Turn-OFF the power on tape unit >GO Turn-ON the power on tape unit and push LOAD and ON-LINE >GO Test Section 6 (Steps 601-628) is complete SECTION 6 (Interactive). Enter: 0-Execute, 1-Skip ? 1 SECTION 7 (Maintenance WRITE/READ). Enter: 0-Execute, 1-Skip ? 1 SECTION 8 (Tape Media Test). Enter: 0-Execute, 1-Skip ? 0 Put a magnetic tape with WRITE RING onto unit under test and push LOAD, ON-LINE and UNIT#0 >GO Reset any another tape unit connected to the same controller >GO No drop-outs in total 615 feet. Test Section 8 (Steps 801-814) is complete >GO ,,1 End of AID user program >9710 EXIT Confirm you want to ERASE the current program(Y or N)?YES Diagnostic/Utility System Revision 03.06 Enter Your Program Name (type HELP for program information) : ---------------------------------- DUS Diagnostics Suite Run Complete ---------------------------------- Goodbye Log file closed